Clearance around electric water heater.
Single wall vents get very hot requiring a 6 in.
Clear the area around your water heater.
Although an electric water heater like the heat pump one shown above is part of a home plumbing system it is an electric appliance.
6 year 120 volt corded point of use mini tank electric water heater model andris rs 4u 1 4kw 209 00 209 00.
Water heaters must be surrounded by a certain amount of clearance or air space to function properly and safely.
Set your store to see local availability add to cart.
Beyond a water heater permit some areas may also require either an electric or plumbing permit depending on the type of water heater.
Unlike other heating devices electric heaters do not require a minimum clearance.
Since water heaters run on electricity or fuel such as oil propane or gas it is important to ensure that your water heater has adequate space for proper ventilation.
Sunday june 17 2018.
Do keep it clean and safe.
What is required clearance for access and working space in front of an electric water heater.
This one today was installed in the ac closet.
Water heater clearance is there a code requirement for space around an electric water heater.
Most water heaters do not have large requirements for combustible clearances.
Basement finishing projects are notorious for this code violation.
A clearance area of 12 inches is required on all sides of a hot water heater.
In order to remove it the air handler would first have to be removed or the wall would have to be removed.
Doors into closets or rooms with water heaters should be wide enough to allow for removal and replacement.
Clearances of less than 6 inches are common.
In an attempt to maximize finished floor space when boxing off the water heater from the rest of the room people often don t leave enough clearance between the new wall framing and the vent pipes.
So the national electrical code requirement nec 110 26 a for equipment likely to require examination adjustment servicing or maintenance while energized applies which specifies a working space 36 deep and 30 wide in front of.
However many electrical equipment codes do recommend the provision of a 30 inch working space on the front and sides of the heater to allow for examination adjustment or maintenance of the electrical equipment.
Some gas units only need 1 inch clearance.
If the space that holds your water heater doubles as a storage or laundry room make sure you keep it organized and clean.
The clearance at the sides back and above a gas water heater are specified by the manufactured in the installation manual and they typically vary from zero to just a few inches.
But a 30 inch by 30 level floor area is required by code at the front service side of the water heater per m1305 1 2 of the international residential code irc and residential edition of the florida building code fbc.
Ariston andris 4 gal.